Description
The Anden Model A130 Dehumidifier is designed to dehumidify the air coming into the unit by passing the incoming air over an evaporator coil to drop the air temperature below the dew point of the air. Moisture is removed from the air and drained out of the unit to a common floor or waste drain. The air is then reheated in the condenser coil and exits the unit. Dehumidification occurs until the set point is reached, then shuts off until periodic sampling determines a need for operation.
Features
- Caster wheels (4) included
- Control (3): Built-in digital control with display
- Control mounting option: Field interchangeable from top to front
- Cabinet insulation:½” EPS
- Air discharge orientation: Top or end
- Inlet/Outlet duct collars: 10″ dia.
- Backdraft damper at outlet: Included
- Filter Washable: MERV 8
- Refrigerant :R410A
- Coil type: E-coated
- Power cord length: 8 ft.
- Discharge air temperature rise 10°F–30°F
- Drain connection(4) ¾” MNPT Threaded
- Warranty: 5 years on all parts including refrigeration system directly from Anden. Store has no role in providing technical support or warranty fulfillment on Anden Dehumidifiers. The end user must contact Anden directly and provide a valid sales receipt or date of manufacture. Stores to deny returns of Anden Dehumidifiers.
- For Help Call: 1-800-972-3710
- Built-in automatic control capable to be set up for dehumidification and ventilation or zoning.
- Threaded barbed fitting included.
Included Items
- Drain fitting: 3/4″ MPT x 3/4″ barbed
- 10′ drain tubing: 3/4″ ID
- Duct collars: 10″ round (A130 only)
- Manual: Installation instruction
Specifications
- Capacity: 130 ppd
- Energy factor: 2.8L/kW-h (5.9 pints/kWh)
- Voltage, phase, frequency: 120VAC, 1 phase, 60Hz
- Current draw(1): 8.3 Amps
- Noise: 50 dBA
- Inlet air operating conditions during: Dehumidification: 50°F-104°F, 40°F dew point min. – Ventilation: 40°F-140°F, 0%-99%RH (non-condensing)
- Dimensions (cabinet only): 19.5″W x 18.75″H (21″ with casters) x 30″L
- Weight: 114 lbs
- Rated capacity and energy factor test done and current draw measured in accordance with AHAM DH-1 2008 at 80°F/60% Rh inlet air at 0.0 ESP.
- Height does not include adjustable feet. The width excludes the filter doors and length excludes the duct collars.
*********SPECIAL ORDER – PREPAID PLEASE!!***********
-
NO RETURN – NO EXCHANGE – NO REFUND